United States-English |
|
|
nPartition Administrator's Guide > Chapter 8 Listing nPartition and Hardware StatusListing Power Status and Power Supplies |
|
You can list power status and power supply details by using any one of the following procedures: Power status and power supply information includes the power status (on or off) for cabinets, cells, and I/O chassis; the status (ok or failed) for power supplies; and related details. Procedure 8-32 Listing Power Status and Power Supplies (Service Processor) From the service processor Command Menu, use the PS command and the cabinet option to list power status and power supply details for the specified cabinet.
Procedure 8-33 Listing Power Status and Power Supplies (nPartition Commands) From the command line, issue the parstatus -B command for a power status summary for all cabinets, or parstatus -V -b# for detailed power status for the specified cabinet (-b#, where # is the cabinet number). You also can issue the frupower -d -C command for cell power status, or the frupower -d -I command for I/O chassis power status. Procedure 8-34 Listing Power Status and Power Supplies (Partition Manager) You can list power status and power supply details by using Partition Manager. When using Partition Manager Version 1.0, use the DetailsShow Complex Details action, Power/Cooling tab to list power details. When using Partition Manager Version 2.0, use the Power and Cooling tab to list power details.
|
Printable version | ||
|